Double check valve assembly
Typical use: Fire sprinklers, lower hazard
Testing: Usually yearly
Test letter from the water district, or a backflow device cracked by frost? We handle backflow testing and prevention in Maine. Fire sprinklers, boilers, irrigation, restaurant equipment and marine businesses can push contaminated water back into the public supply when pressure drops. A backflow preventer stops that reverse flow, and Maine water districts require many of these devices to be tested regularly. We test them, submit results and repair or replace devices that fail.
The service
When main pressure drops, during a break or heavy hydrant use, water inside a building can be drawn back into the public system. A backflow preventer is a set of check valves, sometimes with a relief valve, that blocks that reverse flow. Businesses in Portland (36,559 homes), South Portland and Bangor, and homes with boilers and irrigation, often need one.
Devices we test and install
Typical use: Fire sprinklers, lower hazard
Testing: Usually yearly
Typical use: Boilers, chemicals, high hazard
Testing: Usually yearly
Typical use: Lawn irrigation
Testing: Usually yearly
Typical use: Outdoor faucets
Testing: Replaced if failed
Why Maine
Devices in cold rooms, entryways or outdoors split when they freeze.
Sediment from main work keeps check valves from sealing.
Seals and diaphragms harden and leak over time.
Devices in seasonal buildings sit dry, then stick when restarted.
Warning signs
Our process
A certified tester connects a gauge kit, checks each valve and relief point and records results on your water district's form.
We install the device your district requires for the hazard, in a heated location where possible.
We rebuild devices with new checks, springs and seals or replace frost-cracked bodies, then retest.
Typical cost
Any figure before we see the device is an estimate only. These factors determine the cost:
You approve a written price before we start.
Get a written price: (833) 733-2357RPZ testing takes longer.
Several on one site can be tested together.
Rebuild kits cost less than new devices.
Cracked bodies need replacement.
Some districts charge to record results.
Benefits
Contaminants stay out.
District deadlines are met.
Small problems are caught first.
Proper location prevents freezing.
In Maine, the best place for a backflow device is a heated room. Devices in unheated sprinkler rooms, entry vestibules or crawl spaces split during cold snaps. When we install or replace a device, we locate it where it stays warm or add heat and insulation. Outdoor irrigation devices should be drained before the first hard freeze.
Restaurants, inns and shops in Bar Harbor, Old Orchard Beach (7,796 homes) and other coastal towns often close for winter. Devices must be drained or protected at closing and tested when the water is turned back on. We handle both ends of the season and file test results before you open.
Marinas, boatyards and seafood processors connect hoses to boats, tanks and processing lines that can contaminate the supply. These connections often need high-hazard protection. We install and test devices on dock water lines and processing equipment and plan shutdowns around tides and seasons.
With so many Maine homes and buildings heated by boilers, boiler fill lines are among the most common backflow connections. Boiler water contains treatment chemicals that must not reach the drinking supply. In Lewiston (17,105 homes), Augusta and Bangor, we test and replace these devices during boiler service.
Restaurants, clinics, schools and apartment buildings in Portland, Westbrook (9,575 homes) and other towns have devices on fire lines, soda systems, boilers and equipment. We test several devices per visit and repair on the same visit when parts are on hand, keeping shutdowns short.
Irrigation systems in Gorham (median built 1992), Cape Elizabeth and other suburbs need backflow devices that are tested in spring and drained in fall. We do both and file the results.
Maine water districts and utilities run cross-connection control programs under state drinking water rules, each with its own schedule and forms. We submit results the way your district requires and give you a copy.
Property managers, schools and businesses with several sites in South Portland (12,782 homes), Bangor and elsewhere may have devices due at different times. We keep a list of each device, its location and due date, and group tests to save visits.
Sprinkler systems in apartment buildings, schools, mills converted to housing and offices connect to the public water main through a backflow assembly. Water sitting in sprinkler piping for years can carry rust and treatment chemicals that must stay out of the drinking supply. These assemblies are usually large, and testing them means coordinating with the fire alarm company so the test does not trigger a false alarm. We schedule with your alarm provider, test the assembly, repair or rebuild it if needed and return the system to service the same day.
Many Maine mill buildings in Lewiston, Biddeford, Waterville and Brunswick have become apartments, offices and studios. They often have several water services, old cross-connections from industrial days and sprinkler systems added later. We survey the building, identify connections that need protection and install and test the right devices so the building meets district rules.
When you add a boiler, irrigation, a commercial kitchen or a fire line, your district may require a new device. We install it in a heated, accessible spot, pull the permit and arrange the first test. Choosing the right location at the start saves money later, since a device placed in a cold or cramped corner is harder to test and more likely to freeze.
If the device is spraying, close the valve that feeds it. Clear access to the device.
Have your district's notice handy. Do not adjust the device yourself. Then call us.
New backflow devices usually need a plumbing permit, and testing must be done by a certified tester. We pull permits and submit results. Our plumbers hold Maine plumbing licenses.
Why choose us
What you can count on every time one of our plumbers comes to your door.
Every job is handled by a plumber who holds the license your state or city requires, backed by liability insurance.
Our plumber explains the problem and the options, and you approve a written price before any work begins.
Burst pipes, sewage backups and failed water heaters get priority scheduling, including nights and weekends.
We pull permits when the job needs one and schedule the inspection, so the work holds up when you sell.
Repairs and installations come with a written warranty on labor, on top of the manufacturer's warranty on parts.
Our pages and plumbers account for your area's water, soil, climate and the age of the homes around you.
Service area
We test and repair backflow devices in 155 Maine communities, including Augusta (10,164 homes) and Bar Harbor (1,603 homes). Find yours:
It depends on the device type, the number of devices and how your water district handles reports. We give you a written price before testing.
Usually. Rebuilding with new parts costs less, but a body cracked by frost must be replaced.
Filing is part of our test service. Some districts charge their own record fee, which we tell you about upfront.
Our certified tester briefly shuts off water, connects a gauge kit, checks each valve and records readings. Most tests take under an hour.
Yes. We submit results in the required format and give you a copy.
We explain why, give you a written price for repair or replacement and retest after the work.
It keeps boiler chemicals, fertilizer and dirty water out of drinking water when pressure drops.
It signals a problem or a failing device. Call us to test and repair it.
Usually less than an hour per device. Repairs may add an hour or two.
When the water is turned back on in spring, before opening. We also drain devices at closing.
Keep it in a heated space, or drain it before freezing weather if it serves irrigation.
Most districts require testable devices to be checked every year. Your notice gives the rule.
Close the valve feeding it and call us. Burst devices are scheduled ahead of routine testing.
Boiler fill lines usually need one because boiler water contains chemicals. We test and replace them.
Yes. Dock and boat connections can contaminate the supply, so they often need high-hazard devices.