Reduced pressure zone (RPZ)
Where used: High-hazard uses, boilers, some sprinklers
Notes: Strongest protection; needs drainage
Annual RPZ test notice, or a cracked sprinkler backflow? We do backflow testing and prevention in Illinois for homes, businesses and associations. Illinois water suppliers run cross-connection control programs that require approved backflow assemblies on many connections, tested by state-licensed cross-connection control device inspectors. Lawn sprinklers, fire lines, restaurants, medical offices and boilers are common examples. We test, install, repair and winterize assemblies and file results where required.
The service
Backflow is water flowing the wrong way, from a building into the public supply. A pressure drop from a main break or firefighting can pull it back, and a boiler or pump can push it. Sprinklers, boilers, fire systems and commercial equipment can carry chemicals or bacteria. A backflow assembly stops it. In Illinois, the state plumbing code and Illinois EPA rules require protection, and water suppliers decide how often assemblies are tested.
Common backflow devices
Where used: High-hazard uses, boilers, some sprinklers
Notes: Strongest protection; needs drainage
Where used: Fire lines, lower-hazard uses
Notes: Often in a vault or basement
Where used: Lawn sprinklers
Notes: Above the highest head; winterize
Where used: Outdoor faucets
Notes: Simple protection
Why Illinois
Outdoor sprinkler assemblies left full of water crack in the first hard freeze.
Sediment after main work and hard water deposits keep checks from sealing.
Seals and springs wear with time and temperature swings.
Assemblies in pits and vaults can sit in water, corroding test cocks and bolts.
Warning signs
Our process
Our licensed cross-connection control device inspector attaches gauges to the test cocks, checks each valve and relief opening, records the results and files them where required.
We install the assembly your supplier requires, where it can be tested, drained and protected, with a permit.
We rebuild failed assemblies with new checks, seals and springs or replace cracked bodies, then retest.
Typical cost
You approve a written price before work begins.
Get a written price: (833) 733-2357Several at one site cost less each.
Large RPZs take longer.
Rebuild kits cost less than new bodies.
Blowouts and startups are priced separately.
New installations need one.
Benefits
Your building cannot contaminate the supply.
Tests filed on time.
Proper winterizing.
Every assembly tracked.
Suburbs such as Naperville (57,135 homes), Schaumburg, Orland Park and Aurora have many in-ground sprinkler systems. Each needs a backflow assembly, a yearly test where required and winterizing before the first freeze. We drain the assembly, blow out zones in fall, restart and test in spring, and file results with your village.
Many Chicago (1,277,054 homes) buildings and older homes heat with hot-water boilers that may contain chemical treatment. The boiler feed line needs backflow protection so that water cannot return to the drinking supply. We install and test the right device on boiler fill lines.
Restaurants, salons, clinics, car washes and labs in Peoria (54,010 homes), Springfield, Champaign and Rockford need protection on soda machines, dishwashers, chemical dispensers and medical equipment. We test all assemblies at a site in one visit and keep records.
Fire sprinkler water sits stagnant in the pipes and must not mix with drinking water. Fire line assemblies are tested like others, and we coordinate with the fire protection contractor when systems are shut down.
A backflow assembly on the main line makes the home a closed system. Heated water expands with nowhere to go, so the water heater relief valve drips. An expansion tank fixes it, and we check for one on every main-line install.
Water suppliers track each required assembly. Missed tests can lead to notices and eventually loss of service. We keep a record of every device we test, with location, size, serial number and results, and remind you before the next test is due. For associations and multi-site businesses, that list makes compliance simple.
Spring is the busiest time for sprinkler backflows in Illinois. Turning the system back on too fast can slam the assembly with water hammer, and a crack from winter may not show until the line is pressurized. We open the supply slowly, inspect the assembly for freeze damage, test it and file the report if your village requires one. Combining startup with the annual test saves a visit and catches problems before they flood a basement or yard.
Associations often have several assemblies: on the domestic water main, the fire line, common-area irrigation and pool or clubhouse equipment. Each may have a different due date. We test them together on one visit where possible, give the board a single report and keep a calendar of what is due next. If a device fails, we explain the repair and price it in writing before any work.
Many older commercial and multi-unit buildings have backflow assemblies in underground vaults or meter pits. These can flood, and an RPZ must never sit where its relief port can be submerged, because that defeats its purpose. When we find an RPZ in a pit, we explain the options to move it to a heated room or an insulated above-ground enclosure that drains properly.
Not every risk is a sprinkler. A garden hose left in a bucket of fertilizer, a laundry tub faucet with a hose dropped into the tub, or a water softener drain line pushed into a floor drain without an air gap can all create a path for contamination. We point these out during any visit and fix them with vacuum breakers or proper air gaps.
When a space changes from an office to a restaurant, salon or clinic, the hazard level changes and the water supplier may require a different assembly. We review the plans, install the right device during the build-out and test it before opening, so the backflow item does not hold up your occupancy inspection or delay the first day of business. We also leave you with the test report and permit record that the health and building inspectors may ask to see before they sign off on the space.
If a sprinkler assembly is spraying, close the irrigation shutoff in the basement. Do not plug an RPZ relief port.
Find your test notice and clear access to the assembly. Then call us.
New assemblies need a permit and must be types your supplier approves. Tests are done by inspectors licensed by the Illinois Department of Public Health. Our plumbers hold the licenses Illinois requires.
Why choose us
What you can count on every time one of our plumbers comes to your door.
Every job is handled by a plumber who holds the license your state or city requires, backed by liability insurance.
Our plumber explains the problem and the options, and you approve a written price before any work begins.
Burst pipes, sewage backups and failed water heaters get priority scheduling, including nights and weekends.
We pull permits when the job needs one and schedule the inspection, so the work holds up when you sell.
Repairs and installations come with a written warranty on labor, on top of the manufacturer's warranty on parts.
Our pages and plumbers account for your area's water, soil, climate and the age of the homes around you.
Service area
We test and install backflow assemblies in 1,461 Illinois communities. Choose yours:
It depends on the number, size and type of assemblies. Several at one site lower the cost per device.
A cracked body usually needs a new assembly. Size and type set the price.
Yes, and we often combine it with the yearly test.
Our licensed inspector attaches gauges and checks each valve and relief opening.
Yes, where required. You also get a copy.
Yes. Boiler fill lines need an approved device to protect drinking water.
Yes. It can bring chemicals or bacteria into drinking water.
Never. The discharge is a safety feature. Call us to find the cause.
Usually under an hour per assembly.
Your water supplier sets the schedule, usually yearly.
Before the first hard freeze, usually in October.
When they fail a test or show wear.
Close the irrigation shutoff and call us.
The Illinois Department of Public Health licenses cross-connection control device inspectors.
Water left in outdoor assemblies freezes and splits the body.